Service conditions, electrical ratings, thermal ratings, and environmental testing requirements are defined for communications networking devices to be installed in electric power substations. This standard establishes a common reproducible basis for designing and evaluating communications networking devices and the communications ports of protective relays for use in this harsh environment.
- Sponsor Committee
- PE/PSRCC - Power System Relaying and Control
Learn More - Status
- Inactive-Reserved Standard
- PAR Approval
- 2009-05-11
- Superseding
- 1613-2003
- Amendments
-
1613a-2011
- Board Approval
- 2009-06-17
- History
-
- ANSI Approved:
- 2009-11-10
- Published:
- 2009-08-27
- Inactivated Date:
- 2021-03-25
Additional Resources
- Interpretation
- 1613-2009_interp.pdf
Working Group Details
- Society
- IEEE Power and Energy Society
Learn More - Sponsor Committee
- PE/PSRCC - Power System Relaying and Control
Learn More - Working Group
-
WGI31_P1613 - P1613_ I31_ Standard for Environmental and Testing Requirements for Intelligent Electronic Devices (IEDs) Installed in Transmission and Distribution Facilities
- IEEE Program Manager
- Malia Zaman
Contact - Working Group Chair
- Brian Mugalian
P1613
Standard for Environmental and Testing Requirements for Devices with Communications Functions used with Electric Power Apparatus
This standard specifies ratings and service conditions, environmental performance and testing requirements for devices with communication functions used with electric power apparatus. Environmental and electromagnetic compatibility (EMC) immunity levels and type-tests simulating environments associated with electric apparatus are described. Acceptance criteria for evaluating device functionality are provided. For devices with communication ports, where the device does not perform protection or control functions, testing of the communication functions is covered by IEEE Std 1613. Where the device performs protection or control functions and has communication ports, tests for all communication functions are covered by the IEEE C37.90 family of standards.
1613.1-2013
IEEE Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Transmission and Distribution Facilities
Environmental testing requirements are defined for communications networking devices to be installed in transmission and distribution facilities. This standard establishes a common reproducible basis for designing and evaluating devices utilizing radio frequency (RF) up to 6 GHz, power line communications, and broadband over power line (BPL) technologies. It also requires immunity to five IEC electromagnetic compatibility standards for which there are no IEEE equivalent standards. This standard is an extension to IEEE Std 1613(tm)-2009 and IEEE Std 1613a(tm)-2011.
1613-2003
IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations
Service conditions, electrical ratings, thermal ratings, and environmental testing requirements are defined for communications networking devices to be installed in electric power substations. This standard establishes a common reproducible basis for designing and evaluating communications networking devices for use in this harsh environment.
1613a-2008
IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations Amendment 1: Add Requirements for Altitude and Altitude Derating Factors
This amendment adds requirements to IEEE Std 1613-2003 relating to the altitude of installed communications networking devices, and the derating factors for dielectric power frequency tests and rated maximum ambient temperatures if the installation is above a specified altitude.
1613a-2011
IEEE Standard Environmental and Testing Requirements for Communications Networking Devices Installed in Electric Power Substations Amendment 1: Adding of one definition, DC power supply requirements (5.1), and Annex E- History
This amendment clarifies requirements and explains the rationale for transient test requirements with the addition of one definition, dc power supply requirements (5.1), and Annex E - History.