Inactive-Withdrawn Standard

IEEE 275-1992

IEEE Recommended Practice for Thermal Evaluation of Insulation Systems for Alternating-Current Electric Machinery Employing Form-Wound Preinsulated Stator Coils for Machines Rated 6900 V and Below

A test procedure for comparing two or more insulation systems in accordance with their expected life at rated temperature is described. The procedure is limited to insulation systems for ac electric machines using form-wound preinsulated stator coils and rated 6900 V and below. This procedure is intended to evaluate insulation systems for use in usual service conditions with air cooling. It does not cover such special requirements as machines that are enclosed in gas atmospheres, or that are subjected to strong chemicals, to metal dust, or to submersion in liquids, etc. The procedure includes instructions for testing candidate systems in comparison with known systems having a proven record of service experience and interpretation of the results.

Sponsor Committee
PE/EM - Electric Machinery
Learn More
Status
Inactive-Withdrawn Standard
Superseding
275-1981
Board Approval
1992-06-18
History
Withdrawn:
2004-01-16
ANSI Approved:
1993-01-04
Published:
1992-10-02
Reaffirmed:
1998-09-16

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/EM - Electric Machinery
Learn More
No Active Projects
No Active Standards
No Superseded Standards
No Inactive-Withdrawn Standards
No Inactive-Reserved Standards
Subscribe