Active Standard

IEEE 404-2012

IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kV

Electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage steps from 2.5 kV to 500 kV are established in this standard. In addition, test requirements for joint metallic-shield and jacketing components are defined. A variety of common joint constructions are also defined. This standard has been designed to provide uniform testing procedures that can be used by manufacturers and users to evaluate the ability of underground power cable joints, and associated metallic-shields and jacketing components, to perform reliably in service.

Sponsor Committee
PE/IC - Insulated Conductors
Learn More
Status
Active Standard
PAR Approval
2011-09-10
Superseding
404-2006
Board Approval
2012-03-29
History
Published:
2012-06-18

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/IC - Insulated Conductors
Learn More
Working Group
B02W/404_WG - Working Group for Cable Joints
Learn More
IEEE Program Manager
Ron Hotchkiss
Contact
Working Group Chair
Jeff Madden

P404

IEEE Draft Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kV

Electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage steps from 2.5 kV to 500 kV are established in this standard. In addition, test requirements for joint metallic-shield and jacketing components are defined. A variety of common joint constructions are also defined. This standard has been designed to provide uniform testing procedures that can be used by manufacturers and users to evaluate the ability of underground power cable joints, and associated metallic-shields and jacketing components, to perform reliably in service.

Learn More

No Active Standards

404-2000

IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2500-500 000V

This standard establishes electrical ratings and test requirements of cable joints usedwith extruded and laminated dielectric shielded cable rated in preferred voltage steps from 2500 Vto 500 000 V. It also defines a variety of common joint constructions. This standard is designed toprovide uniform testing procedures that can be used by manufacturers and users to evaluate theability of underground power cable joints to perform reliably in service.

Learn More

404-2006

IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2 500v to 500 000v

This standard establishes electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage steps from 2500 to 500 000V. In addition, it defines test requirements for cable jacket and cable shield restoration devices. It also defines a variety of common joint constructions. This standard is designed to provide uniform testing procedures that can be used by manufacturers and users to evaluate the ability of underground power cable joints, and associated cable shield and cable jacket restoration components, to perform reliably in service.

Learn More

No Inactive-Withdrawn Standards
No Inactive-Reserved Standards
Subscribe

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.