
Electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage steps from 2.5 kV to 500 kV are established in this standard. In addition, test requirements for joint metallic-shield and jacketing components are defined. A variety of common joint constructions are also defined. This standard has been designed to provide uniform testing procedures that can be used by manufacturers and users to evaluate the ability of underground power cable joints, and associated metallic-shields and jacketing components, to perform reliably in service.
- Sponsor Committee
- PE/IC - Insulated Conductors
Learn More - Status
- Active Standard
- PAR Approval
- 2011-09-10
- Superseding
- 404-2006
- Board Approval
- 2012-03-29
- History
-
- Published:
- 2012-06-18
Working Group Details
- Society
- IEEE Power and Energy Society
Learn More - Sponsor Committee
- PE/IC - Insulated Conductors
Learn More - Working Group
-
B02W/404_WG - Working Group for Cable Joints
Learn More - IEEE Program Manager
- Ron Hotchkiss
Contact - Working Group Chair
- Jeff Madden
P404
IEEE Draft Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2.5 kV to 500 kV
Electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage steps from 2.5 kV to 500 kV are established in this standard. In addition, test requirements for joint metallic-shield and jacketing components are defined. A variety of common joint constructions are also defined. This standard has been designed to provide uniform testing procedures that can be used by manufacturers and users to evaluate the ability of underground power cable joints, and associated metallic-shields and jacketing components, to perform reliably in service.
404-2000
IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2500-500 000V
This standard establishes electrical ratings and test requirements of cable joints usedwith extruded and laminated dielectric shielded cable rated in preferred voltage steps from 2500 Vto 500 000 V. It also defines a variety of common joint constructions. This standard is designed toprovide uniform testing procedures that can be used by manufacturers and users to evaluate theability of underground power cable joints to perform reliably in service.
404-2006
IEEE Standard for Extruded and Laminated Dielectric Shielded Cable Joints Rated 2 500v to 500 000v
This standard establishes electrical ratings and test requirements of cable joints used with extruded and laminated dielectric shielded cable rated in preferred voltage steps from 2500 to 500 000V. In addition, it defines test requirements for cable jacket and cable shield restoration devices. It also defines a variety of common joint constructions. This standard is designed to provide uniform testing procedures that can be used by manufacturers and users to evaluate the ability of underground power cable joints, and associated cable shield and cable jacket restoration components, to perform reliably in service.