Superseded Standard

IEEE 450-2002

IEEE Recommended Practice for Maintenance, Testing , and Replacement of Vented Lead-Acid Batteries for Stationary Applications

Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead-acid storage batteries used for standby power applications are provided. This recommended practice also provides guidance to determine when batteries should be replaced. This recommended practice is applicable to full-float stationary applications where a charger maintains the battery fully charged and supplies the dc loads.

Sponsor Committee
PE/ESSB - Energy Storage & Stationary Battery Committee
Learn More
Status
Superseded Standard
PAR Approval
1995-12-12
Superseded by
450-2010
Superseding
450-1995
Board Approval
2002-12-11
History
ANSI Approved:
2003-04-18
Published:
2003-04-03

Additional Resources

Erratas
450-2002_errata.pdf
Interpretation
450-2002_interp.pdf

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/ESSB - Energy Storage & Stationary Battery Committee
Learn More
Working Group
WG_450 - Working Group for Vented Lead Acid Maint and Testing
Learn More
IEEE Program Manager
Michael Kipness
Contact
Working Group Chair
Jason Wallis
No Active Projects

450-2020

IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications

Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead-acid storage batteries used for standby service are provided. Guidance to determine when batteries should be replaced is also provided. This recommended practice is applicable to standby service stationary applications where a charger maintains the battery fully charged and supplies the dc loads.

Learn More

450-2010

IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications

Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead-acid storage batteries used for standby service are provided. This recommended practice also provides guidance to determine when batteries should be replaced. This recommended practice is applicable to standby service stationary applications where a charger maintains the battery fully charged and supplies the dc loads.

Learn More

No Inactive-Withdrawn Standards
No Inactive-Reserved Standards
Subscribe

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.