IEEE/IEC 62271-37-013-2021

IEEE/IEC International Standard for High-voltage switchgear and controlgear--Part 37-013: Alternating current generator circuit-breakers

This part of IEC 62271 is applicable to three-phase AC high-voltage generator circuit-breakers, hereafter called generator circuit-breakers, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV. It is applicable to generator circuit-breakers that are installed between the generator and the transformer terminals. Requirements relative to generator circuit-breakers intended for use with generators and transformers rated 10 MVA or more are covered specifically. Generator circuits rated less than 10 MVA and pumped-storage installations are considered special applications, and their requirements are not completely covered by this document. This document is also applicable to the operating mechanisms of generator circuit-breakers and to their auxiliary equipment.

Sponsor Committee
PE/SWG - Switchgear
Learn More
Status
Active Standard
PAR Approval
2016-12-07
Superseding
62271-37-013-2015
Board Approval
2021-09-23
History
Published:
2021-10-19

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/SWG - Switchgear
Learn More
Working Group
HVCB-WG_C37.013 - HVCB - IEEE Standard for AC High-Voltage (rated above 1000 V) Generator Circuit Breakers for Use with Generators Rated 10 MVA or More
Learn More
IEEE Program Manager
Jennifer Santulli
Contact
Working Group Chair
Mirko Palazzo
No Active Projects
No Active Standards

62271-37-013-2015

IEEE/IEC International Standard for High-voltage switchgear and controlgear -- Part 37-013: Alternating-current generator circuit-breakers

Supersedes IEEE C37.013-1997, and IEC/IEEE 62271-37-013-2015/Cor1-2017.

Learn More

62271-37-013-2015/Cor 1-2017

IEEE/IEC International Standard for high-voltage switchgear and controlgear - Part 37-013: Alternating current generator circuit-breakers: Corrigendum 1

This part of IEC 62271 is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV. It is applicable to generator circuit-breakers that are installed between the generator and the transformer terminals. Requirements relative to generator circuit-breakers intended for use with generators and transformers rated 10 MVA or more are covered specifically. Generator circuits rated less than 10 MVA and pumped storage installations are considered special applications, and their requirements are not completely covered by this standard. This standard is also applicable to the operating mechanisms of generator circuit-breakers and to their auxiliary equipment.

Learn More

C37.013-1997

IEEE Standard for AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis

Ratings, performance requirements, and compliance test methods are provided for ac high-voltage generator circuit breakers rated on a symmetrical current basis that are installed between the generator and the transformer terminals. Guidance for applying generator circuit breakers is given. Pumped storage installations are considered a special application, and their requirements are not completely covered by this standard.

Learn More

No Inactive-Withdrawn Standards
No Inactive-Reserved Standards
Subscribe

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.