Superseded Standard

IEEE C37.106-1987

IEEE Guide for Abnormal Frequency Protection for Power Generating Plants

This guide has been prepared to assist the protection engineer in applying relays for the protection of generating plant equipment from damage caused by operation at abnormal frequencies including over excitation. Emphasis is placed on the protection of the major generating station components at steam generating stations, nuclear stations, and at combustion-turbine installations. Consideration is also given to the effect of abnormal frequency operation on those associated station auxiliaries whose response can affect plant output. The guide also presents background information regarding the hazards caused by operating generating equipment at abnormal frequencies. It documents typical equipment capabilities and describes acceptable protective schemes. Recommended methods for coordinating the under frequency protective scheme with system-load shielding schemes are also included. Sufficient information is provided to apply suitable coordinated protection for given specific situations.

Sponsor Committee
PE/PSRCC - Power System Relaying and Control
Learn More
Status
Superseded Standard
Superseded by
C37.106-2003
Board Approval
1984-03-22
History
ANSI Approved:
1986-09-12
Published:
1987-07-06
Reaffirmed:
1992-06-18

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/PSRCC - Power System Relaying and Control
Learn More
Working Group
C37.106_WG - Abnormal Frequency Protection for Power Generating Plants
Learn More
IEEE Program Manager
Malia Zaman
Contact
Working Group Chair
Ritwik Chowdhury
No Active Projects

C37.106-2022

IEEE Approved Draft Guide for Abnormal Frequency Protection for Power Generating Plants

This guide has been prepared to assist 1 the protection engineer in applying relays for the protection of generating plant equipment from damage caused by operation at abnormal frequencies including overexcitation.

Learn More

No Superseded Standards
No Inactive-Withdrawn Standards

C37.106-2003

IEEE Guide for Abnormal Frequency Protection for Power Generating Plants

Supersedes C37.106-1987 (R1992). This guide has been prepared to assist the protection engineer in applying relays for the protection of generating plant equipment from damage caused by operation at abnormal frequencies including overexcitation.

Learn More