Inactive-Reserved Standard

IEEE C37.110-2007

IEEE Guide for the Application of Current Transformers Used for Protective Relaying Purposes

Revision of IEEE Std C37.110-1996. The characteristics and classification of current transformers (CTs) used for protective relaying are described. This guide also describes the conditions that cause the CT output to be distorted and the effects on relaying systems of this distortion. The selection and application of CTs for the more common protection schemes are also addressed.

Sponsor Committee
PE/PSRCC - Power System Relaying and Control
Learn More
Status
Inactive-Reserved Standard
PAR Approval
1998-12-08
Superseding
C37.110-1996
Corrigendum
C37.110-2007/Cor 1-2010
Board Approval
2007-12-05
History
ANSI Approved:
2008-05-01
Published:
2008-04-07
Inactivated Date:
2021-03-25

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/PSRCC - Power System Relaying and Control
Learn More
Working Group
C37.110_WG-I15 - Working Group for the Application of Current Transformers Used for Protective Relaying Purposes
Learn More
IEEE Program Manager
Malia Zaman
Contact
Working Group Chair
Joseph Valenzuela

PC37.110

IEEE Draft Guide for the Application of Current Transformers Used for Protective Relaying Purposes

The characteristics and classification of current transformers (CTs) used for protective relaying are described. This guide also describes the conditions that cause the CT output to be distorted and the effects on relaying systems of this distortion. The selection and application of CTs for the more common protection schemes are also addressed

Learn More

No Active Standards

C37.90.1-1974

IEEE Standard Surge Withstand Capability Test For Protective Relays and Relay Systems

Two types of design tests for relays and relay systems that relate to the immunity of this equipment to repetitive electrical transients are specified. Test generator characteristics, test waveforms, selection of equipment terminals on which tests are to be conducted, test procedures, criteria for acceptance, and documentation of test results are described. This standard has been harmonized with IEC standards where consensus could be reached.

Learn More

No Inactive-Withdrawn Standards

C37.110-2007/Cor 1-2010

IEEE Guide for the Application of Current Transformers Used for Protective Relaying Purposes Corrigendum 1: Corrections to Equation 18 and Equation 19

Corrigendum to IEEE Std C37.110-2007. Errors in Equation (18) and Equation (19) are corrected by this corrigendum.

Learn More

Subscribe

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.