Superseded Standard

IEEE C37.13.1a-2010

IEEE Standard for Definite-Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear Amendment 1: Revise Short-Circuit Rating and Test Requirement

This amendment to IEEE Std C37.13.1-2006 revises the short-circuit rating and test requirements for definite-purpose switching devices for use in metal-enclosed low-voltage power circuit breaker switchgear.

Sponsor Committee
PE/SWG - Switchgear
Learn More
Status
Superseded Standard
PAR Approval
2008-12-10
Board Approval
2010-06-17
History
ANSI Approved:
2011-06-24
Published:
2010-08-03

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/SWG - Switchgear
Learn More
Working Group
LVSD-WG_C37.13.1 - LVSD - Standard for Definite Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear
Learn More
IEEE Program Manager
Jennifer Santulli
Contact
Working Group Chair
Dan Hrncir
No Active Projects

C37.13.1-2016

IEEE Standard for Definite-Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage (600 V AC and Below) Power Circuit Breaker Switchgear

Definite-purpose switching devices for use in metal-enclosed low-voltage power circuit breaker switchgear are covered in this standard. The switching devices are fused, drawout type, three-pole construction, with one or more rated maximum ac voltages of 600 V, 508 V, and 254 V for application on systems having nominal ac voltages of 600 V, 480 V, and 240 V. The switching devices are power operated with integral or separately mounted overcurrent protective devices. Service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application are addressed in this standard. The switching devices are normally used in applications that require frequency of operation greater than normal operations expected of low-voltage power circuit breakers.

Learn More

C37.13.1-2006

IEEE Standard for Definite Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear

This standard covers definite purpose switching devices for use in metal-enclosed low-voltage power circuit breaker switchgear. The switching devices shall be fused, drawout type, three-pole construction, with one or more rated maximum ac voltages of 600 V, 508 V, and 254 V for application on systems having nominal ac voltages of 600 V, 480 V, and 240 V. The switching devices are power operated with integral or separately mounted overcurrent protective devices. This standard addresses service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application. The switching devices are normally used in applications that require frequency of operation greater than normal operations expected of low-voltage power circuit breakers.

Learn More

No Inactive-Withdrawn Standards
No Inactive-Reserved Standards
Subscribe

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.