IEEE Guide for Testing Metal-Enclosed Switchgear Rated up to 38 kV for Internal Arcing Faults Corrigendum 1

This corrigendum corrects technical errors found in IEEE Std C37.20.7-2007 during use in laboratories concerning current values and arc initiation in low-voltage (LV) testing and supply frequency for all equipment.

Sponsor Committee
PE/SWG - Switchgear
Learn More
Status
Superseded Standard
PAR Approval
2008-09-26
Board Approval
2010-02-02
History
Published:
2010-05-17

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/SWG - Switchgear
Learn More
Working Group
SASC-WG_C37.20.7 - SASC - IEEE Working Group Arc Fault Testing
Learn More
IEEE Program Manager
Jennifer Santulli
Contact
Working Group Chair
Dan Hrncir
No Active Projects

C37.20.7-2017

IEEE Guide for Testing Switchgear Rated Up to 52 kV for Internal Arcing Faults

Procedures for testing and evaluating the performance of switchgear for internal arcing faults is covered. A method of identifying the capabilities of this equipment is given. Service conditions, installation, and application of equipment are also discussed. As used in this document, the term switchgear is used as a general term covering switching and interrupting devices and their combination with associated control, instrumentation, metering, protective and regulating devices, assemblies of those devices with associated interconnections, accessories, and supporting structures used primarily in conjunction with the generation, transmission, distribution, and conversion of electrical power.

Learn More

C37.20.7-2017/Cor 1-2021

IEEE Guide for Testing Switchgear Rated up to 52 kV for Internal Arcing Faults–Corrigendum 1

A procedure for testing and evaluating the performance of switchgear for internal arcing faults is covered. A method of identifying the capabilities of this equipment is given. Service conditions, installation, and application of equipment are also discussed. As used in this document, the term switchgear is used as a general term covering switching and interrupting devices and their combination with associated control, instrumentation, metering, protective and regulating devices, assemblies of those devices with associated interconnections, accessories, and supporting structures used primarily in conjunction with the generation, transmission, distribution, and conversion of electrical power.

Learn More

C37.20.7-2007

IEEE Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults

Revision of IEEE Std C37.20.7-2001. A procedure for testing and evaluating the performance of metal-enclosed switchgear for internal arcing faults is covered. A method of identifying the capabilities of this equipment is given. Service conditions, installation, and application of equipment are also discussed.