Inactive-Reserved Standard

IEEE C37.30.1-2011

IEEE Standard Requirements for AC High-Voltage Air Switches Rated Above 1000 V

Required ratings, construction requirements, design test requirements, applications, and suggested practices for all high-voltage enclosed indoor and outdoor and non-enclosed indoor and outdoor switches rated above 1000 V are specified. This includes ratings and requirements for such switches as disconnecting, selector, horn-gap, and grounding for manual and power operation, except for interrupter switches, distribution-enclosed single-pole air switches, and distribution cutouts fitted with disconnecting blades. Supersedes IEEE Std C37.30-1997, IEEE Std C37.32-2002, IEEE Std C37.34-1994, IEEE Std C37.35-1995, IEEE Std C37.36b-1990, IEEE Std C37.37-1996.

Sponsor Committee
PE/SWG - Switchgear
Learn More
Status
Inactive-Reserved Standard
PAR Approval
2010-09-30
Amendments
C37.30.1a-2017
Board Approval
2011-12-07
History
Published:
2012-03-23
Inactivated Date:
2022-03-24

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/SWG - Switchgear
Learn More
Working Group
HVS-WG_C37.30.1 - HVS - Standard Requirements For High Voltage Air Switches And Interrupting Switches for Alternating Current, Rated Above 1,000 Volts
Learn More
IEEE Program Manager
Jennifer Santulli
Contact
Working Group Chair
Carl Reigart

PC37.30.1

IEEE Draft Standard Requirements for AC High-Voltage Air Switches Rated Above 1,000 V

Required ratings, construction requirements, design test requirements, applications and suggested practices for all high voltage enclosed indoor and outdoor and non-enclosed indoor and outdoor switches rated above 1,000 V are specified. This includes ratings and requirements for such switches as disconnecting, selector, horn-gap, grounding, etc., for manual and power operation, except for interrupter switches, distribution-enclosed single-pole air switches and distribution cutouts fitted with disconnecting blades.

Learn More

No Active Standards
No Superseded Standards
No Inactive-Withdrawn Standards

C37.30.1a-2017

IEEE Standard Requirements for AC High-Voltage Air Switches Rated Above 1000 V -- Amendment 1: Criteria for acceptance

Mechanical operations tests that are applicable for all equipment covered by the complete standard, IEEE Std IEEE C37.30.1(TM)-2011, are covered in this amendment. It further defines criteria for acceptance at the completion of the tests.

Learn More

Subscribe

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.