Superseded Standard

IEEE C57.12.70-2000

IEEE Standard Terminal Markings and Connections for Distribution and Power Transformers

Supersedes C57.12.70-1978 (R1992). Standard terminal markings and connections are described for single-phase and three-phase distribution,power,and regulating transformers.For terminal markings,it covers sequence designation, external terminal designation, neutral terminal designation, grounded terminal designation, and marking of full and tap winding terminals. Additive and subtractive polarity and parallel transformer operation are described.Connections of single-phase transformers in various configurations and angular displacement of three-phase transformers to connect to various system phase displacements are covered.

Sponsor Committee
PE/TR - Transformers
Learn More
Status
Superseded Standard
PAR Approval
1995-06-14
Superseded by
C57.12.70-2011
Superseding
C57.12.70-1978
Board Approval
2000-12-07
History
ANSI Approved:
2001-05-03
Published:
2001-03-16
Reaffirmed:
2006-03-30

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/TR - Transformers
Learn More
Working Group
Stds-WGC57.12.70 - Standard Terminal Markings and Connections for Distribution and Power Working Group
Learn More
IEEE Program Manager
Malia Zaman
Contact
Working Group Chair
Jason Varnell
No Active Projects

C57.12.70-2020

IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers

Standard terminal markings and connections are described for single-phase and three phase distribution, power, and regulating transformers. For terminal markings, it covers sequence designation, external terminal designation, neutral terminal designation, grounded terminal designation, and marking of full and tap winding terminals. Additive and subtractive polarity and parallel transformer operation are described. Connections of single-phase transformers in various configurations and angular displacement of three-phase transformers to connect to various system phase displacements are covered.

Learn More

C57.12.70-2011

IEEE Standard for Standard Terminal Markings and Connections for Distribution and Power Transformers

Standard terminal markings and connections are described for single-phase and three phase distribution, power, and regulating transformers. For terminal markings, it covers sequence designation, external terminal designation, neutral terminal designation, grounded terminal designation, and marking of full and tap winding terminals. Additive and subtractive polarity and parallel transformer operation are described. Connections of single-phase transformers in various configurations and angular displacement of three-phase transformers to connect to various system phase displacements are covered.

Learn More

No Inactive-Withdrawn Standards
No Inactive-Reserved Standards
Subscribe

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.