Active PAR

PC57.142

Guide to Describe the Occurrence and Mitigation of Switching Transients Induced by Transformers, Switching Device, and System Interaction

This Guide addresses the application of transformers in the presence of oscillatory switching transients. These oscillatory transients are typically produced by the interaction of the switching device, transformer, load, and system. This Guide defines operating conditions that may produce switching voltages damaging to the transformer insulation system. It discusses the electrical characteristics of the system source, switching device, transformer, and load and the nature of their transient interaction. It outlines several mitigation methods. Two examples are included. This Guide recognizes that many devices and/or system operations can produce oscillatory transient waveforms. The focus of this Guide is on the interaction between a transformer, the system, and a switching device as a result of several reports of transformer internal winding failures. This Guide focuses only on mechanical switching devices and does not cover semiconductor switching devices.

Sponsor Committee
PE/TR - Transformers
Learn More
Joint Sponsors
PE/SWG
Status
Active PAR
PAR Approval
2017-03-23
Superseding
C57.142-2010

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/TR - Transformers
Learn More
Working Group
PerfCharac-WGC57.142 - Performance Characteristics - Mitigation of Switching Transients CB/Xfrmr Interaction Working Group
Learn More
IEEE Program Manager
Malia Zaman
Contact
Working Group Chair
James Mcbride
No Active Projects
No Active Standards
No Superseded Standards
No Inactive-Withdrawn Standards

C57.142-2010

IEEE Guide to Describe the Occurrence and Mitigation of Switching Transients Induced by Transformers, Switching Device, and System Interaction

The performance of transformers in the presence of oscillatory transients is addressed in this guide. Oscillatory transients are typically produced by the interaction of the switching device, transformer, load, and system. This guide describes operating conditions that may produce oscillatory switching transient voltages damaging to the transformer insulation system. It discusses the electrical characteristics of the source, switching device, transformer, load and the nature of their transient interaction. It discusses several mitigation methods. Two generic examples are included. This guide focuses on mechanical switching devices and does not address semiconductor switching devices.