Series-Connected dry-type air-core single-phase and three-phase outdoor or indoor reactors of distribution and transmission voltage class that are connected in the power system to control power flow under steady-state conditions and/or limit fault current under short-circuit conditions are covered. Dry-Type air-core reactors covered by this standard are self-cooled by natural air convection. With some restrictions, other reactors, including shunt capacitor reactors (used with shunt capacitor banks), filter reactors, shunt capacitor reactors (used with series capacitor banks), and discharge current-limiting reactors, are also covered.
- Sponsor Committee
- PE/TR - Transformers
Learn More - Status
- Superseded Standard
- Superseded by
- C57.16-2011
- Board Approval
- 1996-12-10
- History
-
- ANSI Approved:
- 1997-05-07
- Published:
- 1996-11-30
- Reaffirmed:
- 2001-06-14
Working Group Details
- Society
- IEEE Power and Energy Society
Learn More - Sponsor Committee
- PE/TR - Transformers
Learn More - Working Group
-
DryType-WGC57.16 - Dry Type Transformers - Dry Type Air-Core Reactors Working Group
Learn More - IEEE Program Manager
- Malia Zaman
Contact - Working Group Chair
- J.Arturo DelRio
PC57.16
Standard for Requirements, Terminology, and Test Code for Dry-Type Air-Core Series-Connected Reactors
This standard applies to series-connected dry-type air-core single-phase and three-phase outdoor or indoor reactors of distribution and transmission voltage class that are connected in the power system to control power flow under steady-state conditions and/or limit fault current under short-circuit conditions. Dry-type air-core reactors covered by this standard are self-cooled by natural air convection. With some restrictions, this standard is applicable to filter reactors, shunt capacitor reactors (used with shunt capacitor banks), and discharge current-limiting reactors (used with series capacitor banks). Annex A, Annex B, and Annex C are included to provide guidance. This standard does not apply to devices such as a) Shunt reactors (see IEEE Std C57.21(TM)-2008) b) Arc suppression coils c) Neutral grounding devices (see IEEE Std 32(TM)-1972 [B21]) d) Line resonant reactors e) High-voltage direct current (HVDC) smoothing reactors (IEEE Std 1277(TM)-2010 [B23]) f) Forced cooled reactors g) Line traps and radio interference (RI) filter reactors (ANSI C93.3-1995)
C57.16-2011
IEEE Standard for Requirements, Terminology, and Test Code for Dry-Type Air-Core Series-Connected Reactors
Recommendations are given for reactors intended for series connection, in both transmission and distribution systems, to control power flow under steady-state conditions and/or limit fault current under short-circuit conditions. Dry-type air-core reactors covered by this standard are self-cooled by natural air convection. With some restrictions, other reactors, including filter reactors, shunt capacitor reactors (used with shunt capacitor banks), and discharge current-limiting reactors (used with series capacitor banks) are also covered.