Active Standard

IEEE C57.18.10-2021

IEEE Standard Practices and Requirements for Semiconductor Power Rectifier Transformers

Practices and requirements for semiconductor power rectifier transformers for dedicated loads rated single-phase 100 kW and above and three-phase 100 kW and above are included. Static precipitators, high-voltage converters for dc power transmission, and other nonlinear loads are excluded. Service conditions, both usual and unusual, are specified, or other standards are referenced as appropriate. Routine tests are specified, and an informative annex provides several examples of load loss calculations for transformers when subjected to nonsinusoidal currents, based on calculations provided in the standard.

Sponsor Committee
PE/TR - Transformers
Learn More
Status
Active Standard
PAR Approval
2016-06-30
Superseding
C57.18.10-1998
Board Approval
2021-11-09
History
Published:
2022-03-29

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/TR - Transformers
Learn More
Working Group
PerfCharac-WGC57.18.10 - Performance Characteristics - Semicon Rectifier Xfrmrs Working Group
Learn More
IEEE Program Manager
Malia Zaman
Contact
Working Group Chair
Sheldon Kennedy
No Active Projects
No Active Standards
No Superseded Standards
No Inactive-Withdrawn Standards

C57.18.10-1998

IEEE Standard Practices and Requirements for Semiconductor Power Rectifier Transformers

Practices and requirements for semiconductor power rectifier transformers for dedicated loads rated single-phase 300 kW and above and three-phase 500 kW and above are included. Static precipitators, high-voltage converters for dc power transmission, and other nonlinear loads are excluded. Service conditions, both usual and unusual, are specified, or other standards are referenced as appropriate. Routine tests are specified. An informative annex provides several examples of load loss calculations for transformers when subjected to nonsinusoidal currents, based on calculations provided in the standard.

Learn More

C57.18.10a-2008

IEEE Standard for Practices and Requirements for Semiconductor Power Rectifier Transformers Amendment 1: Added Technical and Editorial Corrections

Amendment to IEEE Std C57.18.10-1998. This standard practice provides rating data, construction requirements, testing, and calculation methods for dry-type or liquid-filled semiconductor power rectifier transformers. These transformers supply nonsinusoidal load currents and are subject to higher harmonic load losses than standard power transformers. A number of examples illustrating harmonic loss calculations are presented in a reference annex.

Learn More

Subscribe

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.