IEEE C57.91-1995/Cor 1-2002

IEEE Guide for Loading Mineral-Oil-Immersed Transformers - Corrigendum 1

Errors identified in IEEE Std C57.91-1995 are addressed in this corrigendum.

Sponsor Committee
PE/TR - Transformers
Learn More
Status
Superseded Standard
PAR Approval
2000-03-30
Board Approval
2002-12-11
History
Published:
2003-06-12
Reaffirmed:
2004-06-24

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/TR - Transformers
Learn More
Working Group
InsLife-WGC57.91 - Insulating Life - Loading Guide Working Group
Learn More
IEEE Program Manager
Malia Zaman
Contact
Working Group Chair
David Wallach

PC57.91

Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators

This guide provides recommendations for loading mineral-oil-immersed transformers and step-voltage regulators with insulation systems rated for a 65 u00b0C average winding temperature rise at rated load. This guide applies to transformers manufactured in accordance with IEEE Std C57.12.00 and tested in accordance with IEEE Std C57.12.90, and step-voltage regulators manufactured and tested in accordance with IEEE Std C57.15. Because a substantial population of transformers and step-voltage regulators with insulation systems rated for 55 u00b0C average winding temperature rise at rated load are still in service, recommendations that are specific to this equipment are also included.

Learn More

No Active Standards

C57.91-1981

IEEE Guide for Loading Mineral-Oil-Immersed Overhead and Pad-Mounted Distribution Transformers Rated 500kVA and Less with 65 C or 55 C Average Winding Rise

General recommendations for loading 65 degrees Centigrade-rise mineral-oil-immersed overhead and pad-mounted distribution transformers are covered. Recommendations for 55 degrees Centigrade-rise transformers are included because a substantial percentage of these transformers are still in service. The recommendations are based on winding hottest-spot calculations only. Other factors that may limit the permissible load to lower values are listed. A method to establish winding temperature and loss of life by nomographs is given.

Learn More

C57.91-1995

IEEE Guide for Loading Mineral-Oil-Immersed Transformers

General recommendations for loading 65 C rise mineral-oil-immersed distribution and power transformers are covered.

Learn More

No Inactive-Withdrawn Standards

C57.91-2011

IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators

This guide provides recommendations for loading mineral-oil-immersed transformers and step-voltage regulators with insulation systems rated for a 65 u00b0C average winding temperature rise at rated load. This guide applies to transformers manufactured in accordance with IEEE Std C57.12.001 and tested in accordance with IEEE Std C57.12.90, and step-voltage regulators manufactured and tested in accordance with IEEE Std C57.15. Because a substantial population of transformers and step-voltage regulators with insulation systems rated for 55 u00b0C average winding temperature rise at rated load are still in service, recommendations that are specific to this equipment are also included.