This standard applies to gas-tube surge-protective devices for application on systems with voltages, 1000 V rms or 1200 V dc.
- Sponsor Committee
- PE/SPDLV - Surge Protective Devices/Low Voltage
Learn More - Status
- Superseded Standard
- PAR Approval
- 2006-09-15
- Superseded by
- C62.31-2020
- Superseding
- C62.31-1987
- Board Approval
- 2006-09-15
- History
-
- ANSI Approved:
- 2007-01-08
- Published:
- 2006-12-08
- Reaffirmed:
- 2011-03-31
Working Group Details
- Society
- IEEE Power and Energy Society
Learn More - Sponsor Committee
- PE/SPDLV - Surge Protective Devices/Low Voltage
Learn More - Working Group
-
LV3.6.1 - 3.6.1 LV Gap Type Surge Protective Device Components WG
Learn More - IEEE Program Manager
- Christian Orlando
Contact - Working Group Chair
- Hans-Wo Oertel
C62.31-2020
IEEE Standard for Test Methods and Preferred Values for Low-Voltage Gas Discharge Tube Surge-Protective Components
This standard applies to low-voltage gas discharge tube (GDT ) surge-protective components for application on systems with voltages less than or equal to 1000 V rms or 1500 V dc. These protective components are designed to limit voltage surges on balanced or unbalanced communication circuits and on power circuits operating from dc to 420 Hz. This standard contains a series of standard test criteria for determining the electrical characteristics and ratings of gas discharge tube surge-protective components.
C62.31-1987
IEEE Standard Test Specification for Gas-Tube Surge Protective Devices
Superseded. Gas-tube surge-protective devices for application on systems with voltages 1000 V rms or 1200 V dc are covered. These protective devices are designed to limit voltage surges on balanced or unbalanced communication circuits and on power circuits operating from dc to 420 Hz. Test criteria for determining the electrical characteristics of these devices are provided.
C62.32-1981
IEEE Standard Test Specifications for Low-Voltage Air Gap Surge-Protective Devices (Excluding Valve and Expulsion Type Devices)
Air gaps for overvoltage protection applications on systems with operating voltages equal to or less than 600 V rms are covered. These protective devices are designed for limiting the voltages on balanced or unbalanced communication, power, and signaling circuits. A series of standard design tests for determining the electrical characteristics of these air gap devices is specified. The tests provide a means of comparison among various air gap surge-protective devices.
C62.32-2004
IEEE Standard Test Methods for Low-Voltage Air Gap Surge-Protective Device Components (Excluding Valve and Expulsion Types)
This standard applies to air gaps for overvoltage protection applications on systems with operating voltages equal to or less than 600 V rms. This standard contains a series of standard tests for determining the electrical characteristics of these air gap devices. This standard's test criteria and definitions provide a common engineering language beneficial to users and manufacturers of air gap surge protective devices.