Tag: Batteries

IEEE 1562-2021

Provided in this recommended practice is information to assist in sizing the array and battery of a stand-alone photovoltaic (PV) system. Systems considered in this recommended practice consist of PV as the only power source and a battery for energy storage. These systems also commonly employ controls to protect the battery from being over- or under-charged and may employ a power conversion subsystem (inverter or converter). This recommended practice is applicable to all stand-alone PV systems where PV is the only charging source. This recommended practice does not include PV hybrid systems nor grid-connected systems. This recommended practice covers lead-acid…

IEEE 937-2019

Design considerations and procedures for storage, location, mounting, ventilation, assembly, and maintenance of lead-acid storage batteries for photovoltaic power systems are provided in this standard. Safety precautions and instrumentation considerations are also included. Even though general recommended practices are covered, battery manufacturers may provide specific instructions for battery installation and maintenance.

IEEE 1013-2019

A method for determining the energy-capacity requirements (sizing) of both vented and valve-regulated lead-acid batteries used in terrestrial stand-alone photovoltaic (PV) systems is described in this recommended practice. Sizing batteries for hybrid or grid-connected PV systems is beyond the scope of this recommended practice. Installation, maintenance, safety, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice. Recommended practices for the remainder of the electrical systems associated with PV installations are also beyond the scope of this recommended practice.

IEEE 1561-2019

This guide is applicable to lead-acid batteries that are used as the energy storage component in remote hybrid power supplies. The remote hybrid application, with its dual generator option, i.e., both renewable and dispatchable generation, is advantageous in that the battery can usually be charged at will and under circumstances that may also be advantageous for the dispatchable generator.

IEEE 1661-2019

This guide is specifically prepared for a PV/engine generator hybrid power system, but may also be applicable to all hybrid power systems where there is at least one renewable power source, such as PV, and a dispatchable power source, such as an engine generator. Taper-charge parameters for PV hybrid systems are suggested to help in preparing the battery for a capacity test. A test procedure is provided to ensure appropriate data acquisition, battery characterization, and capacity measurements. Finally, a process to review test results and make appropriate decisions regarding the battery is provided. No cycle-life predictions are made.

IEEE 535-2013/Cor 1-2017

This corrigenda clarifies the accelerated aging process for duty cycles greater than 8 h.

IEEE 1657-2018

The areas of recommended knowledge for installers and maintainers of stationary batteries and related systems, to the extent that they affect the battery, are defined in this recommended practice. Design of the dc system and sizing of the dc battery charger(s) are beyond the scope of this document. Only lead-acid and nickel-cadmium battery technologies are covered in this recommended practice. An outline (not necessarily in training order) of the items that should be covered by training programs for stationary battery installation and maintenance personnel is provided. Certifying trained personnel and providing its own battery technician training programs will not be…

IEEE 1660-2018

Information on the differences between stationary standby and stationary cycling applications and appropriate battery management strategies in cycling operations is covered in this guide. While the primary emphasis is on lead-acid batteries, information is also provided on alternative and emerging storage technologies. The management of battery systems in stationary standby service is covered in other IEEE documents and is beyond the scope of this guide.

IEEE 450-2020

Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead-acid storage batteries used for standby service are provided. Guidance to determine when batteries should be replaced is also provided. This recommended practice is applicable to standby service stationary applications where a charger maintains the battery fully charged and supplies the dc loads.